Your browser doesn't support javascript.
Show: 20 | 50 | 100
Results 1 - 12 de 12
Filter
1.
Biosensors (Basel) ; 13(5)2023 May 15.
Article in English | MEDLINE | ID: covidwho-20235396

ABSTRACT

Since the global outbreak of coronavirus disease 2019 (COVID-19), it has spread rapidly around the world. The nucleocapsid (N) protein is one of the most abundant SARS-CoV-2 proteins. Therefore, a sensitive and effective detection method for SARS-CoV-2 N protein is the focus of research. Here, we developed a surface plasmon resonance (SPR) biosensor based on the dual signal-amplification strategy of Au@Ag@Au nanoparticles (NPs) and graphene oxide (GO). Additionally, a sandwich immunoassay was utilized to sensitively and efficiently detect SARS-CoV-2 N protein. On the one hand, Au@Ag@Au NPs have a high refractive index and the capability to electromagnetically couple with the plasma waves propagating on the surface of gold film, which are harnessed for amplifying the SPR response signal. On the other hand, GO, which has the large specific surface area and the abundant oxygen-containing functional groups, could provide unique light absorption bands that can enhance plasmonic coupling to further amplify the SPR response signal. The proposed biosensor could efficiently detect SARS-CoV-2 N protein for 15 min and the detection limit for SARS-CoV-2 N protein was 0.083 ng/mL, with a linear range of 0.1 ng/mL~1000 ng/mL. This novel method can meet the analytical requirements of artificial saliva simulated samples, and the developed biosensor had a good anti-interference capability.


Subject(s)
Biosensing Techniques , COVID-19 , Metal Nanoparticles , Humans , Surface Plasmon Resonance/methods , Biosensing Techniques/methods , SARS-CoV-2 , Gold , Immunoassay/methods , COVID-19/diagnosis
2.
IEEE Sens J ; 23(8): 8094-8100, 2023 Apr.
Article in English | MEDLINE | ID: covidwho-2297186

ABSTRACT

A new and reliable method has been constructed for detecting severe acute respiratory syndrome coronavirus type 2 (SARS-CoV-2) open reading frames 1ab (ORF1ab) gene via highly sensitive electrochemiluminescence (ECL) biosensor technology based on highly efficient asymmetric polymerase chain reaction (asymmetric PCR) amplification strategy. This method uses magnetic particles coupled with biotin-labeled one complementary nucleic acid sequence of the SARS-CoV-2 ORF1ab gene as the magnetic capture probes, and [Formula: see text]-labeled amino-modified another complementary nucleic acid sequence as the luminescent probes, and then a detection model of magnetic capture probes-asymmetric PCR amplification nucleic acid products-[Formula: see text]-labeled luminescent probes is formed, which combines the advantages of highly efficient asymmetric PCR amplification strategy and highly sensitive ECL biosensor technology, enhancing the method sensitivity of detecting the SARS-CoV-2 ORF1ab gene. The method enables the rapid and sensitive detection of the ORF1ab gene and has a linear range of 1-[Formula: see text] copies/[Formula: see text], a regression equation of [Formula: see text] = [Formula: see text] + 2919.301 ([Formula: see text] = 0.9983, [Formula: see text] = 7), and a limit of detection (LOD) of 1 copy/[Formula: see text]. In summary, it can meet the analytical requirements for simulated saliva and urine samples and has the benefits of easy operation, reasonable reproducibility, high sensitivity, and anti-interference abilities, which can provide a reference for developing efficient field detection methods for SARS-CoV-2.

3.
Sens Actuators B Chem ; 374: 132800, 2023 Jan 01.
Article in English | MEDLINE | ID: covidwho-2241175

ABSTRACT

Rapid, convenient and accurate detection of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) is urgently needed to timely diagnosis of coronavirus pandemic (COVID-19) and control of the epidemic. In this study, a signal-off photoelectrochemical (PEC) immunosensor was constructed for SARS-CoV-2 nucleocapsid (N) protein detection based on a magnetic all-solid-state Z-scheme heterojunction (Fe3O4@SiO2@TiO2@CdS/Au, FSTCA). Integrating the advantages of magnetic materials and all-solid-state Z-scheme heterostructures, FSTCA was implemented to ligate the capture antibody to form magnetic capture probe (FSTCA/Ab1). It can simplify the separation and washing process to improve reproducibility and stability, while allowing immune recognition to be performed in the liquid phase instead of the traditional solid-liquid interface to improve anti-interference. Besides, the heterojunction inhibited the recombination of photogenerated electron/hole (e-/h+) and promoted the light absorption to provide superior photoelectric substrate signal. The mechanism of photogenerated e-/h+ transfer of FSTCA were investigated by the electron spin resonance (ESR) spectroscopy. SiO2 spheres loaded with Au NPs utilized as an efficient signal quencher. The steric hindrance effect of SiO2@Au labeled detection antibodies (SiO2@Au-Ab2) conjugates significantly diminished light absorption and hindered the transfer of photogenerated electrons, further amplifying the signal change value. Based on the above merits, the elaborated immunosensor had a wide linear range of 10 pg mL-1-100 ng mL-1 and a low detection limit down to 2.9 pg mL-1 (S/N = 3). The fabricated PEC immunosensor demonstrated strong anti-interference, easy operation, and high sensitivity, showing enormous potential in clinical diagnosis of SARS-CoV-2.

4.
Talanta ; 253:N.PAG-N.PAG, 2023.
Article in English | Academic Search Complete | ID: covidwho-2234287

ABSTRACT

The global corona virus disease 2019 (COVID-19) has been announced a pandemic outbreak, and has threatened human life and health seriously. Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), as its causative pathogen, is widely detected in the screening of COVID-19 patients, infected people and contaminated substances. Lateral flow assay (LFA) is a popular point-of-care detection method, possesses advantages of quick response, simple operation mode, portable device, and low cost. Based on the above advantages, LFA has been widely developed for detecting SARS-CoV-2. In this review, we summarized the articles about the sandwich mode LFA detecting SARS-CoV-2, classified according to the target detection objects indicating genes, nucleocapsid protein, spike protein, and specific antibodies of SARS-CoV-2. In each part, LFA is further classified and summarized according to different signal detection types. Additionally, the properties of the targets were introduced to clarify their detection significance. The review is expected to provide a helpful guide for LFA sensitization and marker selection of SARS-CoV-2. [Display omitted] • LFA as a simple user friendly tool is widely employed for SARS-CoV-2 detection. • Present review focus on latest developments in LFAs to detect SARS-CoV-2. • Sensitization strategies and marker properties are beneficial to further research. [ FROM AUTHOR]

5.
Bioelectrochemistry ; 150: 108358, 2023 Apr.
Article in English | MEDLINE | ID: covidwho-2165106

ABSTRACT

A sensitive, reliable, and cost-effective detection for SARS-CoV-2 was urgently needed due to the rapid spread of COVID-19. Here, a "signal-on" magnetic-assisted PEC immunosensor was constructed for the quantitative detection of SARS-CoV-2 nucleocapsid (N) protein based on Z-scheme heterojunction. Fe3O4@SiO2@Au was used to connect the capture antibody to act as a capture probe (Fe3O4@SiO2@Au/Ab1). It can extract target analytes selectively in complex samples and multiple electrode rinsing and assembly steps were avoided effectively. CdTe QDs sensitized TiO2 coated on the surface of SiO2 spheres to form Z-scheme heterojunction (SiO2@TiO2@CdTe QDs), which broadened the optical absorption range and inhibited the quick recombination of photogenerated electron/hole of the composite. With fascinating photoelectric conversion performance, SiO2@TiO2@CdTe QDs were utilized as a signal label, thus further realizing signal amplification. The migration mechanism of photogenerated electrons was further deduced by active material quenching experiment and electron spin resonance (ESR) measurement. The elaborated immunosensor can detect SARS-CoV-2 N protein in the linear range of 0.005-50 ng mL-1 with a low detection limit of 1.8 pg mL-1 (S/N = 3). The immunosensor displays extraordinary sensitivity, strong anti-interference, and high reproducibility in detecting SARS-CoV-2 N protein, which envisages its potential application in the clinical diagnosis of COVID-19.


Subject(s)
Biosensing Techniques , COVID-19 , Cadmium Compounds , Nanocomposites , Quantum Dots , Humans , COVID-19/diagnosis , Electrochemical Techniques , Immunoassay , Limit of Detection , Magnetic Phenomena , Nucleocapsid Proteins , Reproducibility of Results , SARS-CoV-2 , Silicon Dioxide , Tellurium
6.
Anal Methods ; 2022 Dec 05.
Article in English | MEDLINE | ID: covidwho-2151146

ABSTRACT

The rapid spread of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) seriously threatened global public health. Establishing a rapid and sensitive diagnostic test for early detection of the SARS-CoV-2 nucleocapsid protein is urgently required to defend against the pandemic. Herein, an enhanced lateral flow immunoassay (LFIA) was fabricated by trimetallic Au@Pd@Pt core-shell nanozymes for detection of the SARS-CoV-2 nucleocapsid protein. The Au@Pd@Pt nanozymes (Au@Pd@Pt NZs) synthesized via a one-pot method, with a dendrite morphology and uniform particle size, showed excellent peroxidase-like activity. Due to the perfect enzyme-like catalytic activity toward 3,3',5,5'-tetramethylbenzidine (TMB) in the presence of hydrogen peroxide (H2O2), the catalytic signal could be generated even by a tiny amount of Au@Pd@Pt NZs accumulated on the test strip. Therefore, rapid detection with higher sensitivity was achieved. The Au@Pd@Pt NZs-based LFIA provided a quantitative range of 0.05-100 ng mL-1 with a limit of detection of 0.037 ng mL-1, which was 17-fold lower than the LFIA without enhancement. The average recoveries from spiked samples were in the range of 92.5-107.9% with relative standard deviations all less than 4%, indicating the reliability and repeatability of the proposed LFIA. Additionally, the proposed LFIA could report results within 30 min using a microplate reader. In conclusion, the Au@Pd@Pt NZs-LFIA is a rapid, simple, and sensitive method for detecting the SARS-CoV-2 nucleocapsid protein.

7.
Talanta ; : 124051, 2022.
Article in English | ScienceDirect | ID: covidwho-2086748

ABSTRACT

The global corona virus disease 2019 (COVID-19) has been announced a pandemic outbreak, and has threatened human life and health seriously. Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), as its causative pathogen, is widely detected in the screening of COVID-19 patients, infected people and contaminated substances. Lateral flow assay (LFA) is a popular point-of-care detection method, possesses advantages of quick response, simple operation mode, portable device, and low cost. Based on the above advantages, LFA has been widely developed for detecting SARS-CoV-2. In this review, we summarized the articles about the sandwich mode LFA detecting SARS-CoV-2, classified according to the target detection objects indicating genes, nucleocapsid protein, spike protein, and specific antibodies of SARS-CoV-2. In each part, LFA is further classified and summarized according to different signal detection types. Additionally, the properties of the targets were introduced to clarify their detection significance. The review is expected to provide a helpful guide for LFA sensitization and marker selection of SARS-CoV-2.

8.
Toxins (Basel) ; 14(10)2022 10 04.
Article in English | MEDLINE | ID: covidwho-2066493

ABSTRACT

With the outbreak and spread of COVID-19, a deep investigation of SARS-CoV-2 is urgent. Direct usage of this virus for scientific research could provide reliable results and authenticity. However, it is strictly constrained and unrealistic due to its high pathogenicity and infectiousness. Considering its biosafety, different systems and technologies have been employed in immunology and biomedical studies. In this study, phage display technology was used to construct a nonpathogenic model for COVID-19 research. The nucleocapsid protein of SARS-CoV-2 was fused with the M13 phage capsid p3 protein and expressed on the M13 phages. After validation of its successful expression, its potential as the standard for qPCR quantification and affinity with antibodies were confirmed, which may show the possibility of using this nonpathogenic bacteriophage to replace the pathogenic virus in scientific research concerning SARS-CoV-2. In addition, the model was used to develop a system for the classification and identification of different samples using ATR-FTIR, which may provide an idea for the development and evaluation of virus monitoring equipment in the future.


Subject(s)
COVID-19 , Viruses , Humans , SARS-CoV-2/genetics , Cell Surface Display Techniques , Bacteriophage M13/genetics , Bacteriophage M13/metabolism , Capsid Proteins/genetics , Capsid Proteins/metabolism , Nucleocapsid Proteins/genetics , Nucleocapsid Proteins/metabolism
9.
Anal Chim Acta ; 1233: 340486, 2022 Nov 15.
Article in English | MEDLINE | ID: covidwho-2060277

ABSTRACT

The SARS-CoV-2 pandemic has posed a huge challenge to rapid and accurate diagnosis of SARS-CoV-2 in the early stage of infection. In this work, we developed a novel magnetic/fluorescent dual-modal lateral flow immunoassay (LFIA) based on multifunctional nanobeads for rapid and accurate determination of SARS-CoV-2 nucleocapsid protein (NP). The multifunctional nanobeads were fabricated by using polyethyleneimine (PEI) as a mediate shell to combine superparamagnetic Fe3O4 core with dual quantum dot shells (MagDQD). The core-shell structure of MagDQD label with high loading density of quantum dots (QDs) and superior magnetic content realized LFIA with dual quantitative analysis modal from the assemblies of individual single nanoparticles. The LFIA integrated the advantages of magnetic signal and fluorescent signal, resulting excellent accuracy for quantitative analysis and high elasticity of the overall detection. In addition, magnetic signal and fluorescent signal both had high sensitivity with the limit of detection (LOD) as 0.235 ng mL-1 and 0.012 ng mL-1, respectively. The recovery rates of the methods in simulated saliva samples were 91.36%-103.60% (magnetic signal) and 94.39%-104.38% (fluorescent signal). The results indicate the method has a considerable potential to be an effective tool for diagnose SARS-CoV-2 in the early stage of infection.


Subject(s)
COVID-19 , SARS-CoV-2 , Humans , Polyethyleneimine , COVID-19/diagnosis , Immunoassay/methods , Magnetic Phenomena
10.
Sensors and actuators. B, Chemical ; 2022.
Article in English | EuropePMC | ID: covidwho-2045638

ABSTRACT

Rapid, convenient and accurate detection of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) is urgently needed to timely diagnosis of coronavirus pandemic (COVID-19) and control of the epidemic. In this study, a signal-off photoelectrochemical (PEC) immunosensor was constructed for SARS-CoV-2 nucleocapsid (N) protein detection based on a magnetic all-solid-state Z-scheme heterojunction (Fe3O4@SiO2@TiO2@CdS/Au, FSTCA). Integrating the advantages of magnetic materials and all-solid-state Z-scheme heterostructures, FSTCA was implemented to ligate the capture antibody to form magnetic capture probe (FSTCA/Ab1). It can simplify the separation and washing process to improve reproducibility and stability, while allowing immune recognition to be performed in the liquid phase instead of the traditional solid-liquid interface to improve anti-interference. Besides, the heterojunction inhibited the recombination of photogenerated electron/hole (e-/h+) and promoted the light absorption to provide superior photoelectric substrate signal. The mechanism of photogenerated e−/h+ transfer of FSTCA were investigated by the electron spin resonance (ESR) spectroscopy. SiO2 spheres loaded with Au NPs utilized as an efficient signal quencher. The steric hindrance effect of SiO2@Au labeled detection antibodies (SiO2@Au-Ab2) conjugates significantly diminished light absorption and hindered the transfer of photogenerated electrons, further amplifying the signal change value. Based on the above merits, the elaborated immunosensor had a wide linear range of 10 pg mL−1 -100 ng mL−1 and a low detection limit down to 2.9 pg mL−1 (S/N = 3). The fabricated PEC immunosensor demonstrated strong anti-interference, easy operation, and high sensitivity, showing enormous potential in clinical diagnosis of SARS-CoV-2. Graphical

11.
Integrated Ferroelectrics ; 228(1):183-191, 2022.
Article in English | ProQuest Central | ID: covidwho-1960724

ABSTRACT

To quickly and efficiently detect the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) and prevent and control the spread of novel coronavirus disease (COVID-19), a highly sensitive duplex real-time PCR (RT-PCR) detection method has been established. In this study, the specificity of primers and probes were designed, respectively, according to the ORF1ab gene and N gene sequence of SARS-COV-2, and fluorescent probes were labeled with carboxyl fluorescein (FAM) and green fluorescent protein (VIC). The duplex RT-PCR method for detecting SARS-COV-2 with TaqMan probe was established, which has a limit of detection of 10 copies/µL, and the linear detection range of ORF1ab and N gene were 1.0 × 101-1.0 × 105 copies/µL and 1.0 × 101-1.0 × 106 copies/µL, respectively, realizing the simultaneous detection of ORF1ab and N genes in simulated SARS-COV-2 samples. The method has high sensitivity, accurate quantification, simple operation, and cost-saving, which can be used for rapid and efficient quantitative detection of SARS-COV-2.

12.
Sensors (Basel) ; 22(6)2022 Mar 21.
Article in English | MEDLINE | ID: covidwho-1753670

ABSTRACT

To satisfy the need to develop highly sensitive methods for detecting the severe acute respiratory syndrome coronavirus type 2 (SARS-CoV-2) and further enhance detection efficiency and capability, a new method was created for detecting SARS-CoV-2 of the open reading frames 1ab (ORF1ab) target gene by a electrochemiluminescence (ECL) biosensor based on dual-probe hybridization through the use of a detection model of "magnetic capture probes-targeted nucleic acids-Ru(bpy)32+ labeled signal probes". The detection model used magnetic particles coupled with a biotin-labeled complementary nucleic acid sequence of the SARS-CoV-2 ORF1ab target gene as the magnetic capture probes and Ru(bpy)32+ labeled amino modified another complementary nucleic acid sequence as the signal probes, which combined the advantages of the highly specific dual-probe hybridization and highly sensitive ECL biosensor technology. In the range of 0.1 fM~10 µM, the method made possible rapid and sensitive detection of the ORF1ab gene of the SARS-CoV-2 within 30 min, and the limit of detection (LOD) was 0.1 fM. The method can also meet the analytical requirements for simulated samples such as saliva and urine with the definite advantages of a simple operation without nucleic acid amplification, high sensitivity, reasonable reproducibility, and anti-interference solid abilities, expounding a new way for efficient and sensitive detection of SARS-CoV-2.


Subject(s)
Biosensing Techniques , COVID-19 , Biosensing Techniques/methods , COVID-19/diagnosis , Humans , Open Reading Frames/genetics , Reproducibility of Results , SARS-CoV-2/genetics
SELECTION OF CITATIONS
SEARCH DETAIL